Technical data

Manual
Double Sheet Detector R1000 series E20
B0046991 / Rev. 1.6
Electrical installation
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
65
5.4 Wiring diagrams and pin configurations
5.4.1 Wiring diagram Version B, Relay outputs
P42A,P30
(P75V)
19
21
Shield
20
OILFLEX FD810CY 2 x 1 mm²
[Unitronic FDCP (TP) plus 1 x 2 x 1 mm² (UL / CSA)]
LiYCY 17 x 0,25 mm²
Data In
9
10
11
12
13
14
15
16
Max. 250 VAC / 1A
Out 0
Enable
Out 1
Out 2
Out 3
Data Out
4
32
PLC/COM
PLC/COM
IN5
Data In
5
IN0
34
6
7
IN2
8
IN3
33
IN4
IN1
IN6
35
IN7
36
IN8
37
Data Out
IN9
30
IN10
31
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 7
Bit 6
Bit 5
Shield
PLC / COM
System test
Measurement Start
+24 VDC / PLC
(Teach-In)
(Zero adjust)
Meas menue select.
Sensor select. A
Sensor select. B
black (1) [white]
black (2) [brown]
P-Sensor 2
P42A,P30
(P75V)
25
Shield
24
OILFLEX FD810CY 2 x 1 mm²
[Unitronic FDCP (TP) plus 1 x 2 x 1 mm² (UL / CSA)]
black (1) [white]
black (2) [brown]
P-Sensor 3
P42A,P30
(P75V)
27
Shield
26
OILFLEX FD810CY 2 x 1 mm²
[Unitronic FDCP (TP) plus 1 x 2 x 1 mm² (UL / CSA)]
black (1) [white]
black (2) [brown]
P-Sensor 4
P42A,P30
(P75V)
29
Shield
28
OILFLEX FD810CY 2 x 1 mm²
[Unitronic FDCP (TP) plus 1 x 2 x 1 mm² (UL / CSA)]
black (1) [white]
black (2) [brown]
2-Sheets
1-Sheet
0-Sheet
PLC earth ground
PLC R1000
17
18
Earth ground
R1000
>= 1,5 mm²
LiCY 2 x 1 mm²
23
22
+ 24 VDC
0 VDC
external
power supply
Central machine ground
2 (6)
1 (5)
2 (6)
1 (5)
2 (6)
1 (5)
2 (6)
1 (5)
2 (6)
1 (5)
5 ( )
2 (6)
1 (5)
5 ( )
2 (6)
1 (5)
5 ( )
2 (6)
1 (5)
5 ( )
- ( )
- ( )
- ( )
- ( )
Complete wiring is required only if all options are to be used.
The highlighted areas are relevant only for the 4P versions.
Attention The positive supply voltage +24 VDC should not be connected to
machine ground.