Communication with the PLC
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
79
6 Communication with the PLC
Pos: 47 /Doppel blech/Geräte/E2 0/6 Kommuni kation mit der S PS/Kommuni kation mit der S PS - allgemein @ 1\mod_119 2448695562_ 501.doc @ 48 56 @ @ 1
The E20 has 9 (in case of 1P-control unit) or 11 (in case of a 4P-control unit) galvanically isolated
(opto coupled) inputs. For the 4 outputs relays or opto couplers are available as alternatives.
Pos: 48 /Doppel blech/Geräte/E2 0/6 Kommuni kation mit der S PS/Externe E/A - Steuerung @ 1\mod_119 2448692984_ 501.doc @ 48 38 @ 223233334 4333 @ 1
6.1 PLC inputs
For external control parallel PLC inputs are available. These inputs can be operated via a PLC. If
several functions are executed at the same time, then the unit issues an fault message. The
following functions are possible:
Measurement Start / Stop
System test
Menu selection
Teach-in (not active as factory adjustment)
Zero adjust (not active as factory adjustment)
6.2 PLC output signals
The following signals are available as outputs:
Opto coupler outputs
Signal Meaning Note
OUT3 0-sheet output Standard 24 V active (selectable in system configuration)
OUT2 1-sheet output Standard 24 V active (selectable in system configuration)
OUT1 2-sheet output Standard 24 V active (selectable in system configuration)
OUT0 ENABLE output Standard 24 V active (not selectable, for safety reasons)