Communication with the PLC
B0046991 / Rev. 1.6
94
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Pos: 50 /Doppel blech/Geräte/E2 0/5 Elektrisc he Installation/S erielle Schnitts telle RS232 @ 1\ mod_119279 1089078_501. doc @ 5113 @ 233 @ 1
6.5 Serial interface RS232 (version C only)
The serial interface provides all functions necessary for the remote control of the unit. Measuring
programs can be selected and measurement can be started but also changes can be made to
measured values and limits. The following functions are available:
Function Description
“Select program number“ adjusts the desire measurement program
“Measurement Start“ starts the measurement
“Measurement Stop“ switches the measurement off
“Measurement request“ supplies the value of the last measurement
“Adjust nominal thickness“ adjusts the nominal thickness for selected program
“Select sensor no. / sequence“ adjusts the desired sensor number / sequence
“Adjust lower limit in %“ adjusts the relative value of the lower limit (threshold) “low
“Adjust upper limit in %“ adjusts the relative value of the upper limit (threshold) “up“
“Adjust teach-in factor Sensor 1“
adjusts the teach-in for sensor 1
(only the value transferred by the control unit should be re-entered)
“Adjust teach-in factor Sensor 2“
adjusts the teach-in for sensor 2
(only the value transferred by the control unit should be re-entered)
“Adjust teach-in factor Sensor 3“
adjusts the teach-in for sensor 3
(only the value transferred by the control unit should be re-entered)
“Adjust teach-in factor Sensor 4“
adjusts the teach-in for sensor 4
(only the value transferred by the control unit should be re-entered)
“Issue zero adjust command“ starts a zero adjust
“Issue teach-in command“ starts a teach-in
“Request fault message and delete supplies the fault status of the control unit and acknowledges the fault
“Request download“ supplies the download data
“Request current program
supplies the parameters of the current program
(same data format as in the download)
“Request program no. XXX
supplies the parameters of the program no. XXX
(same data format as in the download)
6.5.1 Transmission parameters
The RS232 interface of the R1000 uses the following transmission parameters:
asynchronous transmission
1 Start bit (Low)
8 Data bits (LSB first)
1 Stop bit (High)
300 - 19200 Baud
A parity bit as well as software and hardware handshakes are not available.