Owner's manual

116
MIDI Implementation
3. MIDI Machine Control
MIDI Machine Control Details
STOP(MCS)
Status Data Byte Status
F0H 7FH,Dev,06H,01H F7H
Byte Description
F0H Status of System Exclusive Message
7FH Universal System Exclusive
Realtime Header
Dev Device ID (or 7FH)
06H MMC Command Message
01H STOP (MCS)
F7H EOX (End of Exclusive Message)
If the device ID on the message was as same as that of the receiving device or 7FH, the
VS-2480/2480CD stops immediately.
If the transport switch [STOP] was pressed, the VS-2480/2480CD transmits as the device ID
7FH.
PLAY(MCS)
Status
Data Byte Status
F0H 7FH,Dev,06H,02H F7H
Byte Description
F0H Status of System Exclusive Message
7FH Universal System Exclusive
Realtime Header
Dev Device ID (or 7FH)
06H MMC Command Message
02H PLAY(MCS)
F7H EOX (End of Exclusive Message)
If the device ID on the message was as same as that of the receiving device or 7FH, the
VS-2480/2480CD goes into the playback condition.
The VS-2480/2480CD does not transmit this message.
DEFERRED PLAY(MCS)
Status
Data Byte Status
F0H 7FH,Dev,06H,03H F7H
Byte Description
F0H Status of System Exclusive Message
7FH Universal System Exclusive
Realtime Header
Dev Device ID (or 7FH)
06H MMC Command Message
03H DEFERRED PLAY(MCS)
F7H EOX (End of Exclusive Message)
If the device ID on the message was as same as that of the receiving device or 7FH, the
VS-2480/2480CD goes into the playback condition after the locate operation.
If the transport switch [PLAY] was pressed, the VS-2480/2480CD transmits as the device ID
7FH.
FAST FORWARD(MCS)
Status
Data Byte Status
F0H 7FH,Dev,06H,04H F7H
Byte Description
F0H Status of System Exclusive Message
7FH Universal System Exclusive
Realtime Header
Dev Device ID (or 7FH)
06H MMC Command Message
04H FAST FORWARD(MCS)
F7H EOX (End of Exclusive Message)
If the device ID on the message was as same as that of the receiving device or 7FH, the
VS-2480/2480CD goes into the fast forward condition.
The VS-2480/2480CD does not transmit this message.
REWIND(MCS)
Status
Data Byte Status
F0H 7FH,Dev,06H,05H F7H
Byte Description
F0H Status of System Exclusive Message
7FH Universal System Exclusive
Realtime Header
Dev Device ID (or 7FH)
06H MMC Command Message
05H REWIND(MCS)
F7H EOX (End of Exclusive Message)
If the device ID on the message was as same as that of the receiving device or 7FH, the
VS-2480/2480CD goes into the rewind condition.
The VS-2480/2480CD does not transmit this message.
RECORD STROBE
Status
Data Byte Status
F0H 7FH,Dev,06H,06H F7H
Byte Description
F0H Status of System Exclusive Message
7FH Universal System Exclusive
Realtime Header
Dev Device ID (or 7FH)
06H MMC Command Message
06H RECORD STROBE
F7H EOX (End of Exclusive Message)
If the device ID on the message was as same as that of the receiving device or 7FH, the
VS-2480/2480CD goes into the following condition.
1. The VS-2480/2480CD is in the playback condition. Start Recording the tracks that status
are the record standby mode.
2. The VS-2480/2480CD is in the stop condition. Start Playing back and Start Recording the
track that status are the record standby mode.
If the transport switch [REC] was pressed out of the recording condition, he VS-2480/
2480CD transmits as the device ID 7FH.
RECORD EXIT
Status
Data Byte Status
F0H 7FH,Dev,06H,07H F7H
Byte Description
F0H Status of System Exclusive Message
7FH Universal System Exclusive
Realtime Header
Dev Device ID (or 7FH)
06H MMC Command Message
07H RECORD EXIT
F7H EOX (End of Exclusive Message)
If the device ID on the message was as same as that of the receiving device or 7FH, the
VS-2480/2480CD exit from the record condition.
If the transport switch [REC] was pressed while recording, the VS-2480/2480CD transmits
as the device ID 7FH.
MMC RESET
Status
Data Byte Status
F0H 7FH,Dev,06H,0DH F7H
Byte Description
F0H Status of System Exclusive Message
7FH Universal System Exclusive
Realtime Header
Dev Device ID (or 7FH)
06H MMC Command Message
0DH MMC RESET
F7H EOX (End of Exclusive Message)
If the device ID on the message was as same as that of the receiving device or 7FH, the
VS-2480/2480CD resets all communication channels related with MMC.
When powered on the VS-2480/2480CD transmits as the device ID 7FH.
WRITE
Status
Data Byte Status
F0H 7FH,Dev,06H,40H, F7H
ccH,ddH,eeH,,,ffH,,,
Byte Description
F0H Status of System Exclusive Message
7FH Universal System Exclusive
Realtime Header
Dev Device ID (or 7FH)
06H MMC Command Message
40H WRITE
ccH Information Bytes follows the command
ddH The name of the writable Information Field.
eeH Information Field Format
::
ffH Field names and data
::
F7H EOX (End of Exclusive Message)
If the device ID on the message was as same as that of the receiving device or 7FH, the
VS-2480/2480CD write the data to the specified information field.
The VS-2480/2480CD does not transmit this message.
2480v2_app_e.book 116 ページ 2006年2月7日 火曜日 午後3時33分