Owner's manual

7
Troubleshooting
Troubleshooting
Internal Effects
Effects cannot be used
The VS8F-2 has not been installed correctly.
Only one VS8F-2 has been installed (when EFFECT 3–8
cannot be used).
You are attempting to select the algorithm for Reverb,
Gated Reverb, Vocoder2 (19), Voice Transformer or
Mastering Tool Kit with FX2, FX4, FX6 or FX8.
You are already attempting to select the algorithm for
Vocoder 2 (19), Voice Transformer or Mastering Tool Kit
with FX1, FX3, FX5 or FX7.
I’d like to change the order of an effect algorithm.
The connection orders cannot be altered. They can
only be turned on or off. For more detailed
information on what goes on with the algorithm
orders, please refer to the “Algorithm List” (p. 33).
CD-RW Drive Problems
I made an audio CD on the CD-R/RW
drive, but it doesn’t play on a
consumer CD player.
The finalized process was not carried out. When making
audio CDs, set “FINALIZE” to “On” or “OnlyFin.”.
Audio CD’s created using a CD-RW disc cannot be
played on a conventional CD player. Please use a CD-R
disc.
The CD-R drive is not being recognized
The CD-RW drive is not connected correctly.
The same device ID number is assigned to two or more
SCSI devices (Zip drives , CD-RW drives, etc.).
No CD-R/RW disc is inserted in the drive.
A CD-RW drive that is not designated by Roland.
Cannot write to CD-R discs
The project’s sample rate is set to something other than
44.1 kHz.
No IDE hard disk is installed.
The internal IDE hard disk does not have sufficient free
disk space.
The CD-R disc does not have sufficient free space.
You are trying to write to a commercial CD software
disc.
You are trying to write to a CD-R disc that has been
finalized.
MIDI Devices Problems
With the VS-2480/2480CD as master,
the MIDI sequencer does not respond
to commands
The MIDI cable is not connected correctly.
The MIDI cable is broken.
The MIDI OUT/THRU switch is not set to “Out”.
“MIDI OUT SYNC Gen.” (the MIDI out sync generator)
is not set to the appropriate synchronization method
(MTC, MIDI Clock, Sync Track).
The EXT indicator is blinking (“SYNC MODE” is set to
“EXT”).
The two devices are not set to the same type of MTC
(during MTC synchronization).
The MIDI clock data has not been recorded on the sync
track (if you are using the sync track for
synchronization).
The settings of the MIDI sequencer are not correct.
The MIDI sequencer is not ready to playback.
When synchronizing using a MIDI
sequencer as the master, the VS-2480
does not respond to the sequencer
messages
The MIDI cable is not connected correctly.
The MIDI cable is broken.
You are trying to synchronize using the MIDI clock.
The VS-2480 cannot be run in slave mode using a
method other than MTC.
The EXT indicator is off (“SYNC MODE” is set to
“INT”).
The two devices are not set to the same type of MTC
(during MTC synchronization).
The settings of the MIDI sequencer are not correct.
The VS-2480/2480CD is not in playback standby mode
(with the PLAY indicator blinking).
MTC reception is in poor condition.
Setting the
ERROR LEVEL
to “5” or higher may
improve conditions.
2480v2_app_e.book 7 ページ 2006年2月7日 火曜日 午後3時33分