Reference Manual

Table Of Contents
The transmitter should be mounted with as few internal structures as possible within
the signal beam, see Beam angle and beam width.
Do not mount close to or above the inlet stream.
Do not position the transmitter directly over a side manway door.
Multiple Rosemount 1408H transmitters can be used in the same tank without
interfering with each other.
Figure 3-1: Recommended Mounting Position
L
3.2.2 Free space requirements
If the transmitter is mounted close to a wall or other tank obstruction such as heating coils
and ladders, noise might appear in the measurement signal. See Table 3-1 for
recommended clearance.
Figure 3-2: Free Space Requirements
Table 3-1: Distance to Tank Wall (L)
Minimum Recommended
8 in. (200 mm) ½ of tank radius
Mechanical installation Reference Manual
September 2020 00809-0100-4480
14 Rosemount 1408H Level Transmitter