Reference Manual

Table Of Contents
3.4.4 Mount on a threaded connection
Procedure
1. Grease the transmitter thread with lubricating paste.
Note
The paste must be approved for the application and compatible with the
elastomers used.
2. Mount the transmitter on the tank.
39 mm
Torque 310 in-lb (35 N-m)
Note
Be careful not to scratch or otherwise damage the PTFE sealing.
Reference Manual Mechanical installation
00809-0100-4480 September 2020
Reference Manual 29