Reference Manual

Table Of Contents
7.3.10 Dropping of level close to tank bottom
Symptom
Measured value drops to zero level in the tank bottom region.
Figure 7-10: Symptom
A
B
C
D
A. Level
B. Time
C.
Actual level
D. Reported level
Possible cause
Transmitter has locked on a strong tank bottom echo.
Recommended actions
Verify the Reference Height is configured correctly.
Related information
Reference height
Reference Manual Service and troubleshooting
00809-0100-4480 September 2020
Reference Manual 61