Reference Manual

Table Of Contents
Device reference point
The Device Reference Point is located at the underside of the adapter as illustrated in
Figure C-3.
Figure C-3: Device Reference Point
C.2.3 OUT1 configuration
Output 1 provides a digital output for high/low level limits and IO-Link communication.
Table C-1: Options for OUT1
Option Description
Disabled N/A
Digital Output Normally Open Switching signal for high and low level limits
If set to Disabled, the transmitter may still be operated in IO-Link mode.
Related information
Digital output
C.2.4 OUT2 configuration
Output 2 can perform one of these functions:
Table C-2: Options for OUT2
Option Description
Disabled N/A
Analog Output 4-20 mA Analog 4-20 mA signal proportional to the level
Digital Output Normally Open Switching signal for high and low level limits
Related information
Digital output
Analog output
C.2.5 Digital output P-n
The output polarity for the switching outputs (PnP or nPn).
Reference Manual Configuration parameters
00809-0100-4480 September 2020
Reference Manual 87