Specifications
Table Of Contents
- TWO YEAR LIMITED WARRANTY
- Safety Precautions
- 1. Introduction
- 2. Controls and Functions
- 3. Installation
- 3.1 Remote Control
- 3.2 Quick Setup
- 3.3 Installation Considerations
- 3.4 Installing the Optional CineWide Lens
- 3.5 Mounting the VX-2
- 3.6 Connections to the VX-2 and DHD Controller
- Connector Panel Access
- Connecting the DHD Controller to the VX-2
- Connecting Source Components to the DHD Controller
- RS-232 Controller Connection
- Connecting 12-Volt Trigger Outputs to External Theater Equipment
- Connecting to AC Power
- 4. Operation
- 4.1 Turning on the Power
- 4.2 Adjusting the Picture Orientation
- 4.3 Lens Adjustments
- 4.4 Using the On-Screen Menus
- 5. Maintenance and Troubleshooting
- 6. Serial Communications
- 7. Specifications
- Appendix A. VX-2 Color Gamut Adjustment
![](/manual/runco/video-xtreme-vx-2dcx/specifications-english/images/img-35.png)
Installation
24 Runco VX-2cx/VX-2dcx Owner’s Operating Manual
PRE
L
IMINAR
Y
Vertical and Horizontal Lens Shift - VX-2dcx: Table 3-5 lists the lens shift limits for
each available VX-2dcx lens, as percentages and absolute measurements with a 100 x 56
inch (1.78:1) screen.
Table 3-5. VX-2dcx Vertical and Horizontal Lens Shift Limits
Lens Option
Telesto A Telesto B Telesto C Telesto D Telesto E
Lens Shift Limits, as Percentages of Screen Height or Width (Notes 1 and 2)
Vertical
(Note 2)
Up 0% 25% 40% 35% 18%
Down 0% 55% 90% 110% 110%
Horizontal
(Note 2)
Left 0% 18%
Right 0% 18%
Lens Shift Limits in Inches, with a 100-by-56 inch (1.78:1) Screen
Vertical
Up 0 14 22.4 19.6 10.08
Down 0 30.8 50.4 61.6 61.6
Horizontal
Left 0 18
Right 0 18
Notes:
1. With no vertical or horizontal lens shift, the lens center and screen center are aligned with each
other.
2. Vertical shift limits are percentages of the screen height. Horizontal shift limits are percentages of
the screen width.
3. Vertical lens shift figures apply to ceiling mount configurations. For floor installations
(where the projector is upright), reverse the up/down vertical offset percentages.