Specifications
Table Of Contents
- TWO YEAR LIMITED WARRANTY
- Safety Precautions
- 1. Introduction
- 2. Controls and Functions
- 3. Installation
- 3.1 Remote Control
- 3.2 Quick Setup
- 3.3 Installation Considerations
- 3.4 Installing the Optional CineWide Lens
- 3.5 Mounting the VX-2
- 3.6 Connections to the VX-2 and DHD Controller
- Connector Panel Access
- Connecting the DHD Controller to the VX-2
- Connecting Source Components to the DHD Controller
- RS-232 Controller Connection
- Connecting 12-Volt Trigger Outputs to External Theater Equipment
- Connecting to AC Power
- 4. Operation
- 4.1 Turning on the Power
- 4.2 Adjusting the Picture Orientation
- 4.3 Lens Adjustments
- 4.4 Using the On-Screen Menus
- 5. Maintenance and Troubleshooting
- 6. Serial Communications
- 7. Specifications
- Appendix A. VX-2 Color Gamut Adjustment
Operation
Runco VX-2cx/VX-2dcx Owner’s Operating Manual 43
PRE
L
IMINAR
Y
PLUGE patterns vary but generally consist of some combination of black, white and gray
areas against a black background. The example above includes two vertical bars and four
shaded boxes.
Select Brightness from the Picture menu and press ENTER. Adjust the brightness so that:
• The darkest black bars disappear into the background.
• The dark gray areas are barely visible.
• The lighter gray areas are clearly visible.
• The white areas are a comfortable level of true white.
• The image contains only black, gray and white (no color).
Contrast: On your external test pattern source, select a stepped, gray-bar pattern like the
one shown in
Figure 4-4.
Figure 4-4. Typical Gray Bar Pattern for Adjusting Contrast
Select Contrast and press ENTER. Adjust the contrast to a point just below which the
white rectangle starts to increase in size.
Brightness and contrast controls are interactive. A change to one
may require a subtle change to the other in order to achieve the
optimum setting.
Note