Alarm
Description
Hot Standby
Configuration
This alarm indicates that the hot standby functionality is not properly set up and
includes conflicts with the settings in the other unit. This condition must be handled if
the redundancy shall be meaningful. It will be generated on both R60s in the hot
standby pair.
VHF
Transmission
Monitoring
This alarm indicates the status of the VHF transmission monitoring. If an alarm is
triggered, the transmissions received by the monitoring R60 station differ from the
information that the active R60 station have sent out. This indicates antenna problem
with either the active or the integrity monitoring R60 station. It will be generated on
the active R60 in the hot standby pair.
Time Synch
Indicates the mode of synchronization for the R60 station. Should be ‘UTC direct
unless the base station have problems with the GNSS reception. The indicator will go
yellow if any other means of synchronization is used, such as: UTC Indirect,
Synchronised to a base, or Synchronised to a mobile.
Table 5-1 Description of features monitored in the Alarms sub-category
The alarm indicators are colour coded and the meaning of the different colours are
described in Table 5-2.
Indicator Icon
Meaning
The alarm condition is inactive
The alarm condition is active but not critical to the operation
The alarm condition is active
The alarm is not applicable for the current configuration
Table 5-2 Description of alarm indicator icons
5.3 Monitor > Status
In the Monitor category main page, selecting the Status sub-category will display the
Status view.