Parameter
Description
The features listed below are enabled by setting a tick in the associated box. If
the box is unchecked, the feature associated with that box is disabled.
Output FSR Sentence After Each Frame
Enables/disables output of FSR sentences.
Output Channel Load
Enables/disables Channel Load information (slot usage).
Output Nr of Msgs with Bad CRC
Enables/disables output of number of received messages with bad CRC.
Output Forecast Channel Load
Enables/disables information about total slot (own and others) reservations in
current frame.
Output Average Noise Level
Enables/disables output of average noise level during previous frame.
Output Received Signal Strength
Enables/disables output of number of slots with received signal strength (at
least 10 dB) above the noise level during previous frame.
Table 6-9 Parameters for VSI/FSR category page