Specifications

Chapter 2: Installation
Firmware – S2011 and S3012
Revision: 1 (9/98) 7 © Saftronics, Inc.
2.2 Removing and Replacing the Front Cover
To remove the front cover, first move the Digital Operator in the direction shown by arrow 1. (Figure 5). Then squeeze the cover in
the direction shown by arrows 2 on both sides and lift in the direction shown by arrow 3.
Figure 7 Removing and Replacing the Front Cover
NOTE: Do not replace the front cover with the Digital Operator connected. The Digital Operator will not be connected to the Inverter.
Replace the front cover first and then install the Digital Operator on the cover. See Figure 6 for replacing the Digital Operator.
2.3 Choosing a Location to Mount the Inverter
To ensure proper performance and long operating life, follow the recommendations below when choosing a location for installing the
FP5/GP5. Make sure the Inverter is protected from the following conditions:
o Extreme cold and heat. Use only within ambient temperature range: 10°C to + 40°C.
o Rain, moisture. (For enclosed wall-mounted type.)
o Oil sprays, splashes.
o Salt spray.
o Direct sunlight. (Avoid using outdoors.)
o Corrosive gases or liquids.
o Dust or metallic particles in the air. (For enclosed wall-mounted type.)
o Physical shock, vibration.
o Magnetic noise. (Example: welding machines, power devices, etc.)
o High humidity.
o Radioactive materials.
o Combustibles: thinners, solvents, etc.
efesotomasyon.com - Control Techniques,emerson,saftronics -ac drive-servo motor