Specifications

Chapter 9: Specifications
Firmware – S2011 and S3012
Revision: 1 (9/98) 72 © Saftronics, Inc.
9.1 Standard Specifications
Table 23 200 V Class Specifications
Series FP5/GP5
Models
FP5/GP5
23P7 25P5 27P5 2011 2015 2018 2022 2030 2037 2045 2055 2075
Maximum Applicable Motor
Output *(kW)
3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75
Inverter Capacity (kVA) 6.7 9.5 13 19 24 30 37 50 61 70 85 110
Rated Output Current (A) 17.5 25 33 49 64 80 96 130 160 183 224 300
Maximum Output Voltage 3-Phase, 200/208/220/230 V (Proportional to input voltage)
Output
Characteristics
Rated Output Frequency Up to 400 Hz available by programming
Rated Input Voltage and
Frequency
3-Phase 200/208/220 V 50 Hz
200/208/220/230 V 60 Hz
Allowable Voltage
Fluctuation
+ 10%, 15%
Power
Supply
Allowable Frequency
Fluctuation
± 5%
Control Method Sine wave PWM
Frequency Control Range 0.1 to 400 Hz
Digital Command: 0.01% ( 10°C to + 40°C)
Frequency Accuracy
Analog Command: 0.1% (25°C ± 10°C)
Digital Operator reference: 0.1 Hz
Frequency Resolution
Analog reference: 0.1 Hz
Output Frequency
Resolution
0.1 Hz
Overload Capacity 150% of rated output current for 1 minute 120% of rated output current for 1 minute
Frequency Setting Signal
0 to + 10 V (20k), 4 to 20 mA (250)
Accel/Decel Time 0.0 to 3600 sec (Accel/decel time setting independently)
Braking Torque
Approximately 20%
(Approximately 125% with Braking Resistor)
Approximately 20%
(Braking Resistor cannot be mounted)
Control Characteristics
Number of V/f Patterns 15 preset V/f patterns, 1 custom V/f with voltage limit, 1 custom without voltage limit
Motor Overload
Protection
Protected by electronic Thermal Overload Relay
Instantaneous
Overcurrent
Motor coasts to a stop at approximately 200% of
Inverter rated current.
Motor coasts to a stop at approximately 180% of
Inverter rated current.
Overload
Motor coasts to a stop after 1 minute at 150% of
rated output current.
Motor coasts to a stop after 1 minute at 120% of
rated output current.
Overvoltage Motor coasts to a stop if converter output voltage exceeds 410 V.
Undervoltage Motor coasts to a stop if converter output voltage drops to 190 V or below.
Momentary Power Loss
Immediately stop by 15 ms and above momentary power loss. (Factory setting)
Continuous operation during power loss less than 2 seconds is equipped as standard.
Heatsink Overheat Protected by thermistor.
Stall Prevention Stall Prevention during accel/decel and constant speed operation.
Ground Fault Protected by electronic circuit.
Protective Functions
Power Charge Indication CHARGE LED stays ON until bus voltage drops below 50 V.
Ambient Temperature
10°C to + 40°C (Enclosed wall-mounted type)
10°C to + 45°C (Open chassis type)
Humidity 90% RH or less
Storage Temperature 20°C to + 60°C
Locatioan Indoor (protected from corrosive gases and dust)
Elevation 1000 meters or less
Environment
Vibration 9.81m/s
2
(1G) at 10 to less than 20 Hz, up to 1.96m/s
2
(0.2G) at 20 to 50 Hz.
Based on a Saftronics standard 4-pole motor for maximum applicable motor output.