User's Manual

1 - INSTALLATION AND COMMISSIONING
Installation and User Guide - N56717020101
Page A1-8
No reproduction or communication without the written consent of
SAGEM SA
NOTE: Two LEDs are linked to the "ETH" port:
LED, "Activity", green colour : Trafic status indicator,
LED, "Link", yellow colour : Link status indicator.
1.3.2.2 - Management and Administration ports
"COMM" Interface:
Ports RS232, connecting VT100 standard console or emulation
Bit rate 19200 bauds (8 data bits, no parity bit and 1 stop bit),
Connector Female 9-way HE5
6
5
9
1
Pin N° Signal name Comments
1 DCD Connected to DSR
6 DSR Data Set Ready (to DCE)*
2 RX Received data (to DCE)*
7 RTS Request To Send (from DCE)*
3 TX Transmitted data (from DCE)*
8 CTS Clear To Send (to DCE)*
4 DTR Data Terminal Ready (from DCE)*
9 RI Ring Indicator (not connected)
5 GND Ground
* The ADR155C is seen as DCE
Connection cable See below.
1
9
5
6
1
6
9
5
Wiring diagram
VT100 or PC
side
Male 9-way connector
Equipment side
"COMM"
Female 9-way connector