User's Manual

1 - INSTALLATION AND COMMISSIONING
Installation and User Guide - N56717020101
Page A1-12
No reproduction or communication without the written consent of
SAGEM SA
81
15
9
ADR IC1
1 : NC
2 : TA 9 : TB
3 : TOF PA 10 : TOF PB
4 : RA 11 : RB
5 : ROF PA 12 : ROF PB
6 : R64 A 13 : R64 B
7 : T64 A 14 : T64 B
8 : GND 15 : NC
ADR IC1.1
STATUS
EOW AUX
TR REC
81
15
9
1 : NC
2 : TA 9 : TB
3 : TOF PA 10 : TOF PB
4 : RA 11 : RB
5 : ROF PA 12 : ROF PB
6 : R64 A 13 : R64 B
7 : T64 A 14 : T64 B
8 : GND 15 : NC
TR REC
AUXEOW
STATUS
"
EOW and
"
AUX
"
STM1 transmission port
STM1 reception port
LED STATUS
Green Red
ON OFF Card in service
ON ON Card in alarm
OFF OFF Hardware default (fuse)
OFF ON Card out of service
Flashing Autotest default
"
EOW and
"
AUX
"
Version 1
Version 2
STM1 transmission port
STM1 reception port
LED STATUS
Green Red
ON OFF Card in service
ON ON Card in alarm
OFF OFF Hardware default (fuse)
OFF ON Card out of service
Flashing Autotest default
NC: Reserved
Figure 1-4 - Connecting ADR IC1.x card inputs