User's Manual

2 - OPERATION
Installation and User Guide - N56717020101
No reproduction or communication without the written consent of
SAGEM SA
Page A2-15
Correlation of faults
A correlation mechanism is implemented on all faults detected.
This correlation mechanism, implemented on each change of information collected, is used to
eliminate faults induced by other faults to facilitate fault finding and fault locating.
The following tables define the faults that are masked for each fault detected in the system..
Key :
X : The fault concerned on the current line is masked by the fault in the current
column.
For example: The LOF fault is masked by fault 2 (LOS).
Correlation of STM1 faults
FAULTS
FAULTS
1
TF
2
LOS
3
LOF
4
AIS
5
SD-B2
6
RDI
1TF
2LOS
3LOF X
4 AIS (MS-AIS) X X
5SD-B2 X X X
6 RDI (MS-RDI) X X X
Correlation of MSP faults
FAULTS
FAULTS
1
PAM
2
SCM
3
OTM
1 PAM
2SCM X
3OTM X
Correlation of AU faults
The AU faults are masked by the STM1 LOS, LOF and AIS (MS-AIS) faults.
The TU-LOM fault is filtered, if there is no configured VC12 connection on this STM1.
FAULTS
FAULTS
1
AU-AIS
2
AU-LOP
3
UNEQ
4
RDI
5
SLM
6
TU-LOM
1AU-AIS
2AU-LOP
3 UNEQ (VC4 UNEQ) X X
4 RDI (VC4 RDI) X X X
5SLM XXX
6TU-LOM XXX X