Specifications

ER-5200/ER-5200M series Electronic Cash Register AU Getting Started 19
Initial Clear (Status Clear)
CAUTION: Do not share this information with unauthorized users. Distribute the S Mode
and/or P Mode key only to those you may want to perform this function.
The initial clear function allows you to exit any register activity and return to a beginning or
cleared state. Any transaction that is in progress will be exited and totals for that transaction will not
be updated.
Here are some reasons you may want to perform an initial clear:
The register is in an unknown state, and you wish to exit the current program or transaction
without following normal procedures.
You have performed a function that includes a compulsory activity and you wish to bypass
the compulsion.
An initial clear may be necessary as part of servicing, or troubleshooting.
To Perform an Initial Clear (program restart):
1. Turn the power switch located on the right side of the register to the OFF position.
2. Turn the control lock to the PGM-Mode.
3. Press and hold the key position where the SBTL key is located on the default keyboard
layout.
4. While continuing to hold the SBTL key, turn the power switch to the ON position.
5. The message "INITIAL CLEAR OK!” prints when the initial clear is complete.