User manual

11English
Installation Procedure
Main power terminal block specifications
1-phase terminal block specifications
AC090/100/120/140MXADKH, AC120MXASEH
1(L) 2(N)
F1 F2
LN
15 12 11.4
10.1
3-phase terminal block specifications
AC090/100/120/140MXADNH
1(L) 2(N) L1(R) L2(S) L3(T) N
9.95 11.55 10.1
F1 F2
11.4
Main power cable specifications
The power cable is not supplied with air conditioner.
Select the power supply cable in accordance with relevant local and national regulations.
Wire size must comply with the applicable local and national code.
Specifications for local wiring power cord and branch wiring are in compliance with local cord.
Single phase
Model Outdoor unit Input current (A) Power supply
Indoor unit Outdoor unit Hz
Voltage range (V) Outdoor unit
Indoor unit Total MCA (A) MFA (A)
Rated Min. Max. Cooling Heating
AC090MN4DKH
AC090MXADKH
50 220 to 240 198 264
24.0 24.0
1.0 25.0 25.0
30.0
AC090NN4DKH
1.0 25.0 25.0
AC090MN4PKH
1.5 25.5 25.5
AC090MNMDKH
2.5 26.5 26.5
AC100MN4DKH
AC100MXADKH
1.0 25.0 25.0
AC100NN4DKH
1.0 25.0 25.0
AC100MN4PKH
1.5 25.5 25.5
AC100MNMDKH
2.5 26.5 26.5
AC100MNCDKH
2.0 26.0 26.0
AC100MNTDEH
1.1 25.1 25.1
AC120MN4DKH
AC120MXADKH
1.0 25.0 25.0
AC120NN4DKH
1.0 25.0 25.0
AC120MN4PKH
1.5 25.5 25.5
AC120MNMDKH
2.5 26.5 26.5
AC120MNCDKH
2.0 26.0 26.0
AC120MNMSEH
AC120MXASEH 3.5 27.5 27.5
AC140MN4DKH
AC140MXADKH 32.0 32.0
1.0 33.0 33.0
40.0
AC140NN4DKH
1.0 33.0 33.0
AC140MN4PKH
1.5 33.5 33.5
AC140MNMDKH
2.5 34.5 34.5
AC140MNCDKH
2.0 34.0 34.0