COMMISSION DELEGATED REGULATION (EU) No 626/2011
i)
PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS)
ii)
A
Supplier's name - Samsung Electronics Co.. Ltd.
B
Model name (Indoor/Outdoor) -
AC100MN4DKH /
AC100MXADNH
AC100NN4DKH /
AC100MXADNH
AC100MNMDKH /
AC100MXADNH
AC100MN4PKH /
AC100MXADNH
AC100MNTDEH/
AC100MXADNH
AC120MNCDKH /
AC120MXADKH
C
Sound Power Level (Indoor/Outdoor) dB(A) 61 / 69 61 / 69 58 / 69 61 / 69 65 / 69 62 / 70
D
Refrigerant name
1)
- R-410A R-410A R-410A R-410A R-410A R-410A
E
GWP - 2088 2088 2088 2088 2088 2088
F
SEER - 6.8 6.8 5.8 6.8 5.8 5.7
G
Energy efficiency class (SEER) - A++ A++ A+ A++ A+ A+
H
Q
CE
2)
(cooling season) kWh/a
iii)
515 515 603 515 573 737
I
Pdesignc kW 10.0 10.0 10.0 10.0 9.5 12.0
J
SCOP (Average) - 4.3 4.3 4.0 4.3 4.0 4.1
K
Energy efficiency class SCOP (Average) - A+ A+ A+ A+ A+ A+
L
Q
HE
3)
heating season (Average) kWh/a
iii)
2051 2051 1820 1726 1960 2527
M
Pdesignh (Average) kW 6.3 6.3 5.2 5.3 5.6 7.4
N
Back up heating capacity(Average) kW 0 00000
O
Declared capacity (Average) kW 6.3 6.3 5.2 5.3 5.6 7.4
P
Other heating seasons suitable for use -
'-iv)
Q
SCOP (Warmer) - - - - - - -
R
Energy efficiency class SCOP (Warmer) - ------
S
Q
HE
3)
heating season (Warmer) kWh/a
iii)
------
T
Pdesignh (Warmer) kW ------
U
Back up heating capacity (Warmer) kW ------
V
Declared capacity (Warmer) kW - -----
W
SCOP (Colder) - - - - - - -
X
Energy efficiency class SCOP (Colder) - - -----
Y
Q
HE
3)
heating season (Colder) kWh/a
iii)
------
Z
Pdesignh (Colder) kW - - - - - -
AA
Back up heating capacity (Colder) kW - -----
AB
Declared capacity (Colder) kW ------
1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would
contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.
This appliance contains a refrigerant fluid with a GWP equal to [2088]. This means that if 1 kg of this
refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be [2088] times
higher than 1 kg of CO
2
, over a period of 100 years.
Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always
ask a professional.
2 Energy consumption “XYZ” kWh per year, based on standard test results.
Actual energy consumption will depend on how the appliance is used and where it is located.
3 Energy consumption “XYZ” kWh per year, based on standard test results. Actual energy consumption will depend
on how the appliance is used and where it is located.