COMMISSION DELEGATED REGULATION (EU) No 626/2011
i)
PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS)
ii)
A
Supplier's name - Samsung Electronics Co.. Ltd.
B
Model name (Indoor/Outdoor) -
AC120MN4DKH /
AC120MXADKH
AC120NN4DKH /
AC120MXADKH
AC120MNMDKH /
AC120MXADKH
AC120MN4PKH /
AC120MXADKH
AC120MNCDKH /
AC120MXADNH
C
Sound Power Level (Indoor/Outdoor) dB(A) 61 / 70 61 / 70 62 / 70 61 / 70 62 / 70
D
Refrigerant name
1)
- R-410A R-410A R-410A R-410A R-410A
E
GWP - 2088 2088 2088 2088 2088
F
SEER - 5.7 5.7 5.6 5.7 5.7
G
Energy efficiency class (SEER) - A+ A+ A+ A+ A+
H
Q
CE
2)
(cooling season) kWh/a
iii)
737 737 750 737 737
I
Pdesignc kW 12.0 12.0 12.0 12.0 12.0
J
SCOP (Average) - 4.1 4.1 4.0 4.1 4.1
K
Energy efficiency class SCOP (Average) - A+ A+ A+ A+ A+
L
Q
HE
3)
heating season (Average) kWh/a
iii)
2527 2527 2590 2527 2527
M
Pdesignh (Average) kW 7.4 7.4 7.4 7.4 7.4
N
Back up heating capacity(Average) kW 0 0 0 0 0
O
Declared capacity (Average) kW 7.4 7.4 7.4 7.4 7.4
P
Other heating seasons suitable for use -
'-iv)
Q
SCOP (Warmer) - -----
R
Energy efficiency class SCOP (Warmer) - - - - - -
S
Q
HE
3)
heating season (Warmer) kWh/a
iii)
-----
T
Pdesignh (Warmer) kW - - - - -
U
Back up heating capacity (Warmer) kW -----
V
Declared capacity (Warmer) kW -----
W
SCOP (Colder) - - - - - -
X
Energy efficiency class SCOP (Colder) - - ----
Y
Q
HE
3)
heating season (Colder) kWh/a
iii)
-----
Z
Pdesignh (Colder) kW - - - - -
AA
Back up heating capacity (Colder) kW - - - - -
AB
Declared capacity (Colder) kW - - - - -
1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would
contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.
This appliance contains a refrigerant fluid with a GWP equal to [2088]. This means that if 1 kg of this
refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be [2088] times
higher than 1 kg of CO
2
, over a period of 100 years.
Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always
ask a professional.
2 Energy consumption “XYZ” kWh per year, based on standard test results.
Actual energy consumption will depend on how the appliance is used and where it is located.
3 Energy consumption “XYZ” kWh per year, based on standard test results. Actual energy consumption will depend
on how the appliance is used and where it is located.