Instruction manual

Page 100 of 100 Report No. 255837
TRF No. IEC60335_2_40F
30.1 TABLE: Ball pressure P
Part
Test temperature
(°C)
Impression diameter
(mm)
Allowed impression
diameter (mm)
Cord anchorage 75 < 1,4 2,0
X-capacitor 125 1,5 2,0
Switching transformer bobbin 125 1,4 2,0
Choke coil bobbin 125 1,6 2,0
Relay 125 1,6 2,0
Capacitor for fan motor 125 1,5 2,0
PCB 125 < 1,4 2,0
Terminal block 125 < 1,4 2,0
AC connector 125 1,5 2,0
supplementary information:
30.2 TABLE: glow-wire test P
Parts temperature ( °C) verdict
Cord anchorage 550 P
X-capacitor
850 *) / 750 **)
P
Switching transformer bobbin
850 *) / 750 **)
P
Choke coil bobbin
850 *) / 750 **)
P
Relay
850 *) / 750 **)
P
Capacitor for fan motor
850 *) / 750 **)
P
PCB
850 *) / 750 **)
P
Terminal block
850 *) / 750 **)
P
AC connector
850 *) / 750 **)
P
supplementary information:
*) Glow-wire test at 850 °C according to the IEC 60695-2-11.
No parts exceeding 60 s (te < 60 s) and no parts igniting the layer below.
**) Glow-wire test at 750 °C according to the IEC 60695-2-11.
== END of TEST REPORT ==