Instruction manual

Page 1 of 13 Report No.: 255837
IEC60335_2_40F ATTACHMENT 1
ATTACHMENT TO TEST REPORT IEC 60335-2-40
EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES
Part 2-40: Particular requirements for electrical heat pumps, air conditioners and
dehumidifiers
Differences according to ............... :
EN 60335-2-40:2003 (incl. Corr.:2006) + A11:2004 + A12:2005 +
A1:2006 + A2:2009 with
EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 +
A13:2008
Attachment Form No. .................... :
EU_GD_IEC60335_2_40F
Attachment Originator ................... :
VDE
Master Attachment......................... :
Date 2009-11
Copyright © 2009 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.
EN 60335-1, EN 60335-2-40
Clause Requirement Test Result Remark Verdict
Group Differences / CENELEC COMMON MODIFICATIONS to IEC 60335-1, IEC 60335-2-40
7.12.1
Installation instructions for appliances intended to be
permanently connected to fixed wiring, and have
leakage current exceed 10 mA, state that installation
of residual current device (RCD) having rated
residual operating current not exceeding 30 mA is
advisable (EN 60335-2-40)
Not exceeding 10mA. N/A
For appliances not accessible to the general public
and which are intended to be permanently
connected to fixed wiring and which may have
leakage currents exceeding 10 mA, the installation
instructions shall specify the rating of the residual
current device (RCD) to be installed
(EN 60335-2-40/A12)
Not exceeding 10mA. N/A
13.2 Leakage current measurements (EN 60335-2-40)
(See appended table in main
test report.)
P
15.1
Enclosure provides the degree of moisture protection
according to classification of appliance
(EN 60335-2-40/A2)
No IP degree, IPX0. N/A
Compliance checked as specified in clause 15.1.1,
taking into account 15.1.2, followed by the electric
strength test of 16.3 (EN 60335-2-40/A2)
IPX0 N/A
No trace of water on insulation which can result in a
reduction of clearances and creepage distances
below values specified in clause 29
(EN 60335-2-40/A2)
N/A
15.1.1
Appliances, other than IPX0, subjected to tests as
specified in IEC 60529 (EN 60335-2-40/A2) ............. :
IPX0 N/A