Page 2 of 13 Report No.: 255837
IEC60335_2_40F – ATTACHMENT 1
EN 60335-1, EN 60335-2-40
Clause Requirement – Test Result – Remark Verdict
Water valves containing in external hoses for
connection of an appliance to water mains,
subjected to the test as specified for IPX7 appliances
(EN 60335-2-40/A2)
No such water valves. N/A
15.1.2
Hand-held appliance turned continuously through
most unfavourable positions during test
N/A
Built-in appliances installed according instructions
(EN 60335-2-40/A2)
IPX0 N/A
Appliances placed or used on the floor or table
placed on a horizontal unperforated support
(EN 60335-2-40/A2)
N/A
Appliances normally fixed to a wall and appliances
with pins for insertion into socket-outlets are
mounted on a wooden board (EN 60335-2-40/A2)
N/A
For IPX3 appliances, the base of wall mounted
appliances is placed at the same level as the pivot
axis of the oscillating tube (EN 60335-2-40/A2)
N/A
For IPX4 appliances, horizontal centre line of
appliance is aligned with pivot axis of oscillating tube
(EN 60335-2-40/A2)
N/A
However, for appliances normally used on floor or
table, movement is limited to two times 90 ° for a
period of 5 min, support being placed at the level of
pivot axis of oscillating tube (EN 60335-2-40/A2)
N/A
Appliances normally fixed to a ceiling are mounted
underneath a horizontal unperforated support, pivot
axis of oscillating tube located at level of underside
of support (EN 60335-2-40/A2)
N/A
IPX4 appliances, movement of tube is limited to two
times 90 ° from vertical for a period of 5 min
(EN 60335-2-40/A2)
N/A
Wall-mounted appliances, take into account distance
to floor stated in instructions (EN 60335-2-40/A2)
N/A
Appliances with type X attachment fitted with a
flexible cord as described (EN 60335-2-40/A2)
N/A
Detachable parts tested as specified
(EN 60335-2-40/A2)
N/A
15.2
Appliances proof against humid conditions
(EN 60335-2-40)
Considered. P
Humidity test for 48 h in a humidity cabinet
(EN 60335-2-40)
For 48h at 24°C, 95% R.H.
P
Appliance withstands tests of clause 16
(EN 60335-2-40)
No excessive leakage current.
No breakdown.
P
16.2 Leakage current measurements (EN 60335-2-40)
(See appended table in main
test report.)
P