Instruction manual

Page 3 of 13 Report No.: 255837
IEC60335_2_40F ATTACHMENT 1
EN 60335-1, EN 60335-2-40
Clause Requirement Test Result Remark Verdict
24.1.7
Remote operation via telecommunication network,
relevant standards for telecommunication interface
circuitry in appliance EN 41003 and
EN 60950-1:2006, Subclause 6.3 (EN 60335-1/A13)
No such remote operation. N/A
25.6
Supply cords of single-phase portable appliances having a rated current not
exceeding 16 A, fitted with a plug complying with the following standard sheets of
IEC 60083:1975:
- class I appliances: standard sheet C2b, C3b or C4 : Stationary/ Fixed appliance. N/A
- class II appliances: standard sheet C5 or C6 ......... : N/A
25.7 Supply cords being one of following types:
- ordinary polychloroprene sheathed flexible cord (at
least 60245 IEC 57) (H05RN-F)
1. Not checked in this test
report.
2. The manufacturer, service
agent or similarly qualified
person shall use a proper
cross sectional area of supply
cord and interconnection cord
referring to an installation
manual.
N/A
Supply cords having high flexibility, not lighter than:
- rubber insulated and sheathed cord (60245 IEC 86)
(H03RR-H)
N/A
- rubber insulated, crosslinked PVC sheathed cord
(60245 IEC 87) (H03RV4-H)
N/A
- crosslinked PVC insulated and sheathed cord
(60245 IEC 88) (H03V4V4-H).
N/A
29.3 Replace third dashed item by:
- an assessment of thermal quality of material
combined with an electric strength test, in
accordance with clause 29.3.3, and for accessible
reinforced insulation consisting of a single layer,
measurement in accordance with clause 29.3.Z1
(EN 60335-1/A12)
N/A
29.3.Z1
Accessible reinforced insulation consisting of a
single layer, thickness of layer complies with
table Z1; rated voltage (V); overvoltage category;
thickness (mm) (EN 60335-1/A12) ............................ :
N/A
GG.2
Requirements for charge limits in unventilated areas
(EN 60335-2-40/A1)
Intended for the use of a non-
flammable refrigerant.
N/A
GG.Z1
Non fixed factory sealed single package units with a
charge amount of m
1
< M 2 x m
1
(EN 60335-2-40/A1)
N/A