Page 5 of 13 Report No.: 255837
IEC60335_2_40F ATTACHMENT 1
EN 60335-1, EN 60335-2-40
Clause Requirement Test Result Remark Verdict
25.6
Supply cords of single-phase portable appliances having a rated current not
exceeding 13 A provided with a plug according to following:
- Class I appliances: Section 107-2-D1, ed.3 1998,
standard sheet DK 2-1a
No plugs.
The manufacturer, service
agent or similarly qualified
person shall use a proper
cross sectional area of supply
cord and interconnection cord
referring to an installation
manual.
N/A
Appliances covered by a Part 2 of EN 60335, also
plugs in accordance with Section 107-2-D1, ed.3,
1998, standard sheet C2b, C3b or C4 are allowed
N/A
Class II appliances: Section 107-2-D1, ed.3 1998,
standard sheet C1b, C5, C6, DKA 2-1a and
DKA 2-1b
N/A
Stationary single-phase appliances, having a rated
current not exceeding 13 A, and provided with a
supply cord and a plug, the plug is in accordance
with the requirements above
N/A
Multi-phase appliances and single-phase appliances having a rated current
exceeding 13 A, and provided with a supply cord and a plug, plug is in accordance
with requirements below:
- Class I appliances: Section 107-2-D1, standard
sheet DK 6-1a / EN 60309-2, standard sheet 2-II,
2-IV
No plugs.
The manufacturer, service
agent or similarly qualified
person shall use a proper
cross sectional area of supply
cord and interconnection cord
referring to an installation
manual.
N/A
- Class II appliances: Section 107-2-D1, standard
sheet DK 6-1a / EN 60309-2, standard sheet 2-II,
2-IV, the earthing contact not being connected
N/A
Current for plug not exceeding values specified;
standard sheet (no.); current (A) ................................ :