Instruction manual

Page 6 of 13 Report No.: 255837
IEC60335_2_40F ATTACHMENT 1
EN 60335-1, EN 60335-2-40
Clause Requirement Test Result Remark Verdict
National Differences / Deviations for Finland
ZA
ANNEX ZA (NORMATIVE), SPECIAL NATIONAL CONDITIONS (EN 60335-1,
EN 60335-2-40)
25.6 Plugs according to standard sheet C3b not allowed
No plugs.
The manufacturer, service
agent or similarly qualified
person shall use a proper
cross sectional area of supply
cord and interconnection cord
referring to an installation
manual.
N/A
National Differences / Deviations for France
ZA
ANNEX ZA (NORMATIVE), SPECIAL NATIONAL CONDITIONS (EN 60335-1,
EN 60335-2-40)
22.2
Second paragraph of this subclause, dealing with
single-phase, permanently connected class I
appliances having heating elements, not applicable
due to supply system
No heating elements. N/A
25.6 Plugs according to standard sheet C2b not allowed
No plugs.
The manufacturer, service
agent or similarly qualified
person shall use a proper
cross sectional area of supply
cord and interconnection cord
referring to an installation
manual.
N/A
National Differences / Deviations for Germany
ZA
ANNEX ZA (NORMATIVE), SPECIAL NATIONAL CONDITIONS (EN 60335-1,
EN 60335-2-40)
25.6 Plugs according to standard sheet C3b not allowed
No plugs.
The manufacturer, service
agent or similarly qualified
person shall use a proper
cross sectional area of supply
cord and interconnection cord
referring to an installation
manual.
N/A
ZB ANNEX ZB (INFORMATIVE), A-DEVIATIONS (EN 60335-1, EN 60335-2-40)
29.3
GERMANY: Third dashed item not applicable for
appliances where the insulation is accessible.
Additional measures, such as multi-layered
insulation or adequate thickness, taken
(EN 60335-1/A1)
N/A