Instruction manual

Page 12 of 13 Report No.: 255837
IEC60335_2_40F ATTACHMENT 1
EN 60335-1, EN 60335-2-40
Clause Requirement Test Result Remark Verdict
According to guideline 1/39 of the directive, this
exclusion applies to both components and
assemblies (refrigerant circuits). This applies to
appliances containing vessels (e.g. compressors,
receivers) or piping with limits in accordance with
the following (EN 60335-2-40/A11):
N/A
Vessels (EN 60335-2-40/A11)
- dangerous refrigerants (Annex II, Table 1) (EN 60335-2-40/A11):
- volume not exceeding 1 l, or
(EN 60335-2-40/A11)
N/A
- pressure x volume not exceeding 5 MPa l
(EN 60335-2-40/A11)
N/A
- non-dangerous refrigerants (Annex II, Table 2) (EN 60335-2-40/A11):
- volume not exceeding 1 l, or
(EN 60335-2-40/A11)
N/A
- pressure x volume not exceeding 20 MPa l
(EN 60335-2-40/A11)
N/A
Piping (EN 60335-2-40/A11)
- dangerous refrigerants (Annex II, Table 6) (EN 60335-2-40/A11):
- numerical designation not exceeding 25, or
(EN 60335-2-40/A11)
N/A
- pressure not exceeding 1 MPa and numerical
designation not exceeding 100, or
(EN 60335-2-40/A11)
N/A
- pressure exceeding 1 MPa and pressure x
numerical designation not exceeding 100 MPa
(EN 60335-2-40/A11).
N/A
- non-dangerous refrigerants (Annex II, Table 7) (EN 60335-2-40/A11):
- numerical designation not exceeding 100, or
(EN 60335-2-40/A11)
N/A
- pressure x numerical designation not exceeding
350 MPa (EN 60335-2-40/A11).
N/A
For other components, the most onerous limit of the
two applies (EN 60335-2-40/A11)
N/A
The volume is the internal volume of the vessel and
includes the volume of pipework up to the first
connection. It excludes the volume of fixed internal
parts (EN 60335-2-40/A11)
N/A
The pressure is the maximum pressure the vessel
or piping system is exposed to, as specified by the
manufacturer of the appliance
(EN 60335-2-40/A11)