Instruction manual

Page 1 of 14
Report No. 255837
IEC60335_1S ATTACHMENT 2
Clause Requirement - Test Result - Remark Verdict
ATTACHMENT TO TEST REPORT IEC 60335-1
EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES
Household and similar electrical appliances Safety
Part 1: GENERAL REQUIREMENTS
Differences according to :
EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 +
A13:2008 + A14:2010 + A15:2011
EN 50366:2003 + A1:2006 or
EN 62233:2008
Attachment Form No. :
EU_GD_IEC60335_1S
Attachment Originator :
Nemko
Master Attachment :
Date 2011-12
Copyright © 2011 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.
CENELEC COMMON MODIFICATIONS (EN)
6.1 Delete “class 0” and “class 01”
Class I appliance.
P
7.1 Single-phase appliances to be connected to the
supply mains: 230 V covered
220-240 V~
230 V covered.
P
Multi-phase appliances to be connected to the
supply mains: 400 V covered
220-240 V~
N/A
19.14 If a relay or contactor with more than one contact is
used, all contacts are short-circuited at the same
time
P
24.1 Unless otherwise specified, the requirements of
Clause 29 apply between live parts of components
and accessible parts of the appliance
The such components applied
between live parts of
components and accessible
parts of the appliance.
P
Unless otherwise specified, the requirements of
30.2 apply to parts of non-metallic material in
components including parts of non-metallic material
supporting current-carrying connections inside
components
The such components applied
to parts of non-metallic
material in component
including parts of non-metallic
material supporting current-
carrying connections inside
components.
P
Components that have not been tested or do not
comply with the relevant component standard are
tested according to the requirements of 30.2
The such components tested
according to the requirements
of 30.2.
P