IEC60335_1S ATTACHMENT 2
Clause Requirement - Test Result - Remark Verdict
- halogen-free thermoplastic compound sheathed
cords (H05Z1Z1H2-F, H05Z1Z1-F), for other
appliances
N/A
Cross-linked halogen-free compound sheathed
supply cords have properties at least those of
cross-linked halogen free compound sheathed
cords (H07ZZ-F)
N/A
26.2 Conductors connected by soldering are not
considered to be positioned or fixed so that reliance
is not placed upon the soldering alone to maintain it
in position unless they are held in place near the
terminals independently of the solder
N/A
26.11 Conductors connected by soldering are not
considered to be positioned or fixed so that reliance
is not placed upon the soldering alone to maintain it
in position unless they are held in place near the
terminals independently of the solder
N/A
29.2 In a double insulation system, the working voltage
for both the basic insulation and supplementary
insulation is taken as the working voltage across
the complete double insulation system
P
29.3 The third dashed item replaced by:
- an assessment of the thermal quality of the
material combined with an electric strength test, in
accordance with 29.3.3, and, for accessible
reinforced insulation consisting of a single layer,
measurement in accordance with 29.3.Z1
N/A
29.3.Z1 For accessible reinforced insulation consisting of a
single layer, the thickness of the layer complies with
table Z1; rated voltage (V); overvoltage category;
thickness (mm) :
N/A
32 Compliance regarding electromagnetic fields is
checked according to EN 50366 or EN 62233
See annex EN 62233:2008. P