Instruction manual

Page 11 of 14
Report No. 255837
IEC60335_1S ATTACHMENT 2
Clause Requirement - Test Result - Remark Verdict
19.11.4.8 The appliance continues to operate, without causing
any hazard to the user, from the same point in its
operating cycle at which the voltage fluctuation
occurred, or
P
a manual operation is required to restart it P
20.1 Appliances and their components and fittings have
adequate mechanical stability during transportation,
assembly, dismantling and any other action
involving the appliance
P
20.2 Dangerous moving transmission parts safeguarded
either by design or guards
P
When guards are used, they are fixed guards,
interlocking movable guards or protective devices
P
Moving parts directly involved in the function of the appliance which cannot be made
completely inaccessible fitted with:
- fixed guards or interlocking movable guards
preventing access to those sections of the parts
that are not used in the work, and
P
- adjustable guards restricting access to those
sections of the moving parts where access is
necessary
P
Interlocking movable guards used where frequent
access is required
P
21.1 Appliances and their components and fittings have
adequate mechanical strength and is constructed to
withstand such rough handling that may be
expected in normal use, during transportation,
assembly, dismantling, scrapping and any other
action involving the appliance
P
22.ZE.1 For appliances provided with a seat, the seat gives
adequate stability
N/A
The distance between the seat and the control
devices capable of being adapted to the operator
N/A
22.ZE.2 For appliances provided with separate devices for
the start and the stop functions, the stop function is
unambiguously identifiable and does always
override the start function
N/A
For appliances provided with one device performing
the start and the stop function, the stop function is
unambiguously identifiable and does always
override the start function
N/A