IEC60335_2_40F ATTACHMENT 3
National Difference of Australia (AU)
AS/NZS 60335.1:2002 corresponding to IEC 60335-1:2002; am1; am2
Clause Requirement Test Result Verdict
5.2
Replace the last paragraph of NOTE 1 with the
following variation:
If the tests of annex H are carried out, one switch or
one additional appliance is needed.
N/A
5.8.1 Replace with the following variation:
Appliances for a.c. only are tested with a.c. at 50
Hz, and those for a.c. and d.c. are tested at a.c. 50
Hz or d.c., whichever is the more unfavourable
supply.
Rated: 220-240V~ 50Hz
Tested with a.c. at 50Hz.
P
5.201 For Australia the following applies:
For appliances, other than class III appliances, that are intended for connection to
the supply mains and that are not marked with
a rated voltage of at least 240 V for single-phase
appliances and at least 415 V for three-phase
appliances, or
N/A
a rated voltage range that includes 240 V for
single-phase appliances and 415 V for three-phase
appliances,
Rated: 220-240V~ 50Hz P
the rated voltage is equal to 240 V for single-phase
appliances and 415 V for three-phase appliances,
and the upper limit of the rated voltage range is
equal to 240 V for single-phase appliances and
415 V for three-phase appliances.
Upper limit: 240V~ 50Hz P
In addition, the rated current or rated power input is
equal to the calculated value corresponding to 240
V for single-phase appliances and 415 V for three-
phase appliances as appropriate.
N/A
NOTE 1 Example of calculation
If the appliance is marked with a rated voltage of
230 V and a rated current "A" or a rated power
input "P", it will be tested as if it is marked with a
rated voltage of 240 V and a rated current of A x
(240/230) or a rated power input of P x (240/230)2.
6.1
Replace the requirement with the following
variation:
Appliances shall be of one of the following classes
with respect to protection against electric shock:
class I, class II, class III.
Class I appliance. P
7.1 After the first paragraph of the requirement insert the following variation:
Appliances intended for connection to the supply mains, other than class III
appliances, shall be marked with
a rated voltage of at least:
230 V for single phase appliances;
400 V for polyphase appliances, or
N/A