Instruction manual

Page 3 of 4 Report No.: 255837
IEC60335_2_40F ATTACHMENT 3
National Difference of Australia (AU)
AS/NZS 60335.1:2002 corresponding to IEC 60335-1:2002; am1; am2
Clause Requirement Test Result Verdict
a rated voltage range that includes:
230 V for single phase appliances;
400 V for polyphase appliances.
Rated: 220-240V~ 50Hz P
7.13
Replace the requirement with the following
variation:
Instructions and other text required by this standard
shall be written in English.
In English. P
Table 3
After the second row in table 3 insert the following
variation:
Insulated pins of appliances with pins
for insertion into socket-outlets…………. 45
No socket-outlets. N/A
22.3
Replace the first paragraph of the test specification
with the following variation:
Compliance is checked by inserting the pins of the
appliance into a socket-outlet capable of accepting
a plug complying with Figure 2.1(a) of AS/NZS
3112. The socket-outlet has a horizontal pivot at a
distance of 8 mm behind the engagement face of
the socket-outlet and in the plane of the lower
intersection of the centre lines of the contact
apertures.
No socket-outlets. N/A
22.201 After Clause 22.45 insert the following variations:
22.201 VOID
22.202
Appliances having integral pins for insertion into
socket outlets shall comply with the appropriate
requirements of AS/NZS 3112.
No socket-outlets. N/A
Compliance with checked as specified in Annex J of
AS/NZS 3112
N/A
NOTE 1 Clause J.2.2.3 (Internal connections for
plug portions) of AS/NZS 3112 is covered by clause
23 of this standard
N/A
NOTE 2 Clause J.2.2.6.2 (High voltage test) of
AS/NZS 3112, except for the test of the insulation
of the insulated pins, is covered by clause 16 of this
standard.
N/A
NOTE 3 Clause J.2.2.6.4 (Temperature rise test)
of AS/NZS 3112 is covered by clause 11 of this
standard
N/A
NOTE 4 Clause J.2.2.6.7 (Equipment with integral
pins intended to be supported by the contacts of a
socket-outlet) of AS/NZS 3112 is covered by clause
22.3 of this standard
N/A