Page 4 of 4 Report No.: 255837
IEC60335_2_40F ATTACHMENT 3
National Difference of Australia (AU)
AS/NZS 60335.1:2002 corresponding to IEC 60335-1:2002; am1; am2
Clause Requirement Test Result Verdict
24.1 Before Note 1, insert the following variation.
NOTE 201 The relevant IEC standard may be
replaced with the relevant Australia/New Zealand
standard where applicable.
24.1.7 Add the following variation to the test specification:
In Australia, telecommunication interface circuitry
must comply with the Telecom Labelling Notice
issued under the Telecommunications Act instead
of IEC 62151.
No telecommunication
network operation.
N/A
NOTE 201 The Telecommunications Act is
administered by the Australian Communications
and Media Authority.
N/A
25.1 After the requirement insert the following variation.
Supply cords for single-phase portable appliances
intended for direct connection to the supply mains,
shall be fitted with an appropriate plug complying
with AS/NZS 3112.
Fixed/ Stationary appliance. N/A
Table 11 Replace footnote a with the following variation:
a
These cords may only be used if their length does
not exceed 2 m between the point where the cord
or cord guard enters the appliance and the entry to
the plug. However, they cannot be used in class I
appliances.
Class I appliance,
And it shall be provided with
supply cord/ interconnection
cord exceeding 2m.
N/A
Note)
This national deviation was declared by IECEE Member NCB: SAI-Global,
Last modification: 2010-04-19