Instruction manual

Page 14 of 100 Report No. 255837
TRF No. IEC60335_2_40F
IEC 60335-2-40
Clause Requirement Test Result Verdict
Model or type reference ........................................... : (Indoor unit)
a) AM056FNLDEH;
b) AM045FNLDEH;
c) AM036FNLDCH;
d) AM028FNLDCH;
e) AM022FNLDCH
P
Symbol 5172 of IEC 60417, for class II appliances
Class I appliance. N/A
Symbol IEC 60417-5036, for the enclosure of
electrically-operated water valves in external
hose-sets for connection of an appliance to the water
mains (IEC 60335-1/A1)
Not intended to be connected
to the water mains.
N/A
Mass of refrigerant or of each refrigerant in blend
(except for azeotropic type) (IEC 60335-2-40) ........ :
Not checked in the appliance N/A
Refrigerant identification (IEC 60335-2-40) ............. :
Not checked in the appliance N/A
Permissible excessive operating pressure for
sanitary hot water heat pumps (IEC 60335-2-40) ... :
Not such an appliance. N/A
Maximum operating pressure for heat exchanger for
hydronic fan coil/air handling units
(IEC 60335-2-40/A2) ................................................ :
No hydronic unit. N/A
Permissible excessive operating pressure of
refrigerant circuit for suction and discharge, if they
differ (IEC 60335-2-40) ............................................ :
Not marked with marking plate
for indoor unit.
N/A
Symbol for degree of protection against ingress of
water, other than IPX0 (IEC 60335-2-40) ................ :
IPX0 for indoor unit. N/A
Separate marking of appliances with all rated
characteristics of supplementary heaters
(IEC 60335-2-40)...................................................... :
No supplementary haters. N/A
Marking of direction of fluid flow (IEC 60335-2-40)
It can be distinguished from the
different diameter of pipes.
N/A
Flame symbol and instruction manual symbol of 7.6 visible when flammable
refrigerant employed and following conditions exist (IEC 60335-2-40/A1):
- accessing parts expected to be subjected to
maintenance or repair (IEC 60335-2-40/A1);
Intended for the use of a non-
flammable refrigerant.
N/A
- observing appliance under sale or installed
conditions (IEC 60335-2-40/A1);
N/A
- observing appliance packaging, if appliance
charged with refrigerant (IEC 60335-2-40/A1).
N/A
If flammable refrigerant used, symbols for “read
operator’s manual”, “operator’s manual; operating
instructions” and “service indicator; read technical
manual” (symbols 0790, 1641 and 1659 of
ISO 7000) placed on appliance in location visible to
persons required to know information. Perpendicular
height be at least 10 mm (IEC 60335-2-40/A1 corr.1)
N/A