Instruction manual

Page 21 of 100 Report No. 255837
TRF No. IEC60335_2_40F
IEC 60335-2-40
Clause Requirement Test Result Verdict
10 POWER INPUT AND CURRENT
10.1
Power input at normal operating temperature, rated
voltage and normal operation not deviating from
rated power input by more than shown in table 1
(See appended table)
P
Deviation of appliance with one or more rated
voltage ranges (IEC 60335-1/A2)
Rated: 220 240 V or
208 230 V
Measured at arithmetic mean
value of the rated voltage
range.
P
10.2
Current at normal operating temperature, rated
voltage and normal operation not deviating from
rated current by more than shown in table 2
(See appended table)
P
Deviation of appliance with one or more rated
voltage ranges (IEC 60335-1/A2)
Rated: 220 240 V or
208 230 V.
Measured at arithmetic mean
value of the rated voltage
range.
P
11 HEATING
11.1
No excessive temperatures in normal use
(IEC 60335-2-40)
No excessive temperatures. P
Compliance is checked by the tests of annex C, if (IEC 60335-2-40):
- temperature of motor winding exceeds values
shown in table 3 (IEC 60335-2-40)
Not exceeded. N/A
- there is doubt about classification of insulation
system of the motor (IEC 60335-2-40)
No doubt about the
classification of insulation
system of motors.
N/A
11.2 Placing and mounting of appliance (IEC 60335-2-40):
- clearances to adjacent surfaces (IEC 60335-2-40);
Installed in accordance to the
manual.
P
- flow rates for liquid source or sink equipment be
minimum, except for fan coils where flow rates and
liquid temperatures be maximum
(IEC 60335-2-40/A2);
No means for adjustment. N/A
- static pressures (IEC 60335-2-40);
N/A
- means of adjusting the flow, flow for tests be
minimum obtainable (IEC 60335-2-40);
N/A
- adjustable limit controls set at maximum cut-out
setting and minimum differential (IEC 60335-2-40).
No adjustable limit controls. N/A
Appliances with supplementary heaters, use test
casing of clause 11.9 (IEC 60335-2-40)
No supplementary heaters. N/A
11.2.1
Appliances with supplementary heaters, inlet duct
connected to inlet air opening (IEC 60335-2-40)
No supplementary heaters. N/A