Instruction manual

Page 22 of 100 Report No. 255837
TRF No. IEC60335_2_40F
IEC 60335-2-40
Clause Requirement Test Result Verdict
11.2.2
Appliance without supplementary heaters, air outlet
used (IEC 60335-2-40)
N/A
11.3
Temperature rise determine by thermocouples or
resistance method (IEC 60335-2-40)
By thermocouple method and
resistance method.
P
11.4
Test performed at supply voltage between 0,94 and
1,06 times the rated voltage (IEC 60335-2-40)
Tested as this clause. P
Heating elements energized at voltage which gives
an electrical input of 1,15 times maximum rated
power input (IEC 60335-2-40)
Motor operated appliance. N/A
11.5
Test conducted in heating mode and cooling mode, if
both exist (IEC 60335-2-40)
At both lowest cooling and
highest heating mode.
P
All supplementary heating elements operative
simultaneously (IEC 60335-2-40)
No supplementary heaters. N/A
11.6
Defrost test in most unfavourable conditions, if
needed (IEC 60335-2-40)
N/A
11.7
Appliances operated continuously until steady
conditions except for defrost tests (IEC 60335-2-40)
Operated until steady
conditions are established.
P
11.8
Temperatures not exceeding values of table 3
(IEC 60335-2-40/A2)
(See appended tables)
P
Protective devices do not operate (IEC 60335-2-40)
Not operated. P
Sealing compound not flowing out (IEC 60335-2-40)
P
Temperature of air in outlet duct not exceed 90 °C
(IEC 60335-2-40)
N/A
11.9
Test casing and installation of appliances in
accordance with manufacturer’s instructions
(IEC 60335-2-40)
Not considered. N/A
Glass fibre insulation for appliances without
indication of minimum clearances according to
manufacturer; thermocouple in contact with
enclosure (IEC 60335-2-40)
N/A
13
LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING
TEMPERATURE
13.1
Leakage current not excessive and electric strength
adequate
P
Heating appliances operated at 1,15 times rated
power input ............................................................... :
No heating elements. N/A
Motor-operated appliances and combined
appliances supplied at 1,06 times rated voltage ..... :
1,06 x 240V~ 50/60Hz P
Protective impedance and radio interference filters
disconnected before carrying out the tests
P
13.2
Leakage current measured by means of the circuit
described in figure 4 of IEC 60990
Tested by this measurement
circuit.
P