IEC 60335-2-40
Clause Requirement Test Result Verdict
19.7
Test of air to air appliances at rated voltage or at the
upper limit of the rated voltage range. Dry-bulb
temperature is 5 K below values specified by
manufacturer (IEC 60335-2-40)
Results: No hazard.
No severe temperature rise.
P
Test with the dry-bulb temperature 10 K over the
values specified by manufacturer (IEC 60335-2-40)
(see appended table)
Results: No hazard.
No severe temperature rise.
P
19.8
Test of appliances with supplementary heaters
(IEC 60335-2-40)
No supplementary heaters. N/A
19.9
Test at temperature permitting continuous operation
of the motor-compressor and electric heating
elements at same time (IEC 60335-2-40)
No supplementary heaters. N/A
19.10
Test of appliance with any defect which expected
during normal use (IEC 60335-2-40)
(see appended table)
Results: No hazard.
No severe temperature rise.
P
19.10.101
Test of clause 19.10 repeated on class 0I appliances
and class I appliances incorporating tubular
sheathed or embedded heating elements
(IEC 60335-2-40/A2)
No heating elements. N/A
However, controls not short-circuited but one end of
element connected to sheath of heating element
(IEC 60335-2-40/A2)
N/A
Test repeated with polarity of supply to appliance
reversed and with other end of element connected to
sheath (IEC 60335-2-40/A2)
N/A
Test not carried out on appliances intended to
permanently connected to fixed wiring and on
appliances where an all-pole disconnection occurs
during test of clause 19.10 (IEC 60335-2-40/A2)
N/A
19.11
Electronic circuits, compliance checked by
evaluation of the fault conditions specified in
clause 19.11.2 for all circuits or parts of circuits
(IEC 60335-2-40), unless
(see appended table)
Results: No hazard.
No severe temperature rise.
P
they comply with conditions specified in
clause 19.11.1 (IEC 60335-2-40)
N/A
Windings temperature not exceeding values shown
in table 8 (IEC 60335-2-40)
P
Appliance comply with conditions of clause 19.14
(IEC 60335-2-40)
P
Appliance withstands test: a conductor becomes
open circuited and three conditions are met
(IEC 60335-2-40)
N/A