TRF No. IEC60335_2_40F
IEC 60335-2-40
Clause Requirement Test Result Verdict
19.11.1
Before applying the fault conditions a) to f) in 19.11.2, it is checked if circuits or parts
of circuit meet both of following conditions (IEC 60335-2-40):
- electronic circuit is low-power circuit, that is,
maximum power at low-power points not exceed
15 W according to tests specified (IEC 60335-2-40)
N/A
- protection against electric shock, fire hazard,
mechanical hazard or dangerous malfunction in
other parts of appliance does not rely on correct
functioning of electronic circuit (IEC 60335-2-40)
N/A
19.11.2
Fault conditions applied one at a time, appliance operated under conditions specified
in clause 11, but supplied at rated voltage, duration of tests as specified
(IEC 60335-2-40):
a) short circuit of creepage distances and clearances
between live parts of different potential, if these
distances less than values specified in
clause 29.1, unless relevant part is adequately
encapsulated (IEC 60335-2-40)
N/A
b) open circuit at terminals of any component
(IEC 60335-2-40)
P
c) short circuit if capacitors, unless they comply with
IEC 60384-14 (IEC 60335-2-40)
Complying with IEC 60384-14. N/A
d) short circuit of any two terminals of an electronic
component, other than integrated circuits. This
fault condition not applied between circuits of an
optocoupler (IEC 60335-2-40)
P
e) failure of triacs in diode mode (IEC 60335-2-40)
N/A
f) failure of an integrated circuit. Possible hazardous
situations of appliance assessed to ensure that
safety not rely on correct functioning of such
component (IEC 60335-2-40)
P
Short-circuit of low-power circuits (IEC 60335-2-40)
N/A
Duration of tests (IEC 60335-2-40):
- as specified in clause 11.7 but only for one
operating cycle, if fault cannot recognised by user
(IEC 60335-2-40);
P
- as specified in clause 19.2, if fault can recognised
by user (IEC 60335-2-40);
P
- until steady conditions stablished (IEC 60335-2-40).
P
Test ended if interruption of supply occurs within the
appliance (IEC 60335-2-40)
P
If electronic circuit operates to ensure compliance
with clause 19, relevant test repeated with single
fault a) to f) simulated (IEC 60335-2-40)
N/A
Fault condition f) applied to encapsulated or similar
components (IEC 60335-2-40)
N/A