Instruction manual

Page 31 of 100 Report No. 255837
TRF No. IEC60335_2_40F
IEC 60335-2-40
Clause Requirement Test Result Verdict
- a statement in the instruction sheet that a
disconnection incorporated in the fixed wiring is to
be provided
P
- an appliance inlet
No appliance inlet. N/A
Singe-pole switches and single-pole protective
devices for disconnection of heating elements in
single-phase, permanently connected class 0I and I
appliances, connected to phase conductor
(IEC 60335-1/A2)
N/A
22.3
Appliance provided with pins: no undue strain on
socket-outlets
N/A
Applied torque not exceeding 0,25 Nm
N/A
Pull force of 50 N to each pin after the appliance has
being placed in the heating cabinet; when cooled to
room temperature the pins are not displaced by
more than 1 mm
N/A
Each pin subjected to a torque of 0,4 Nm; the pins
are not rotating unless rotating does not impair
compliance with the standard
N/A
22.4
Appliance for heating liquids and appliance causing
undue vibration not provided with pins for insertion
into socket-outlets
No heating liquids or undue
vibration.
N/A
22.5
No risk of electric shock when touching pins of plug,
for appliances having a capacitor with rated
capacitance exceeding 0,1 µF, appliance being
disconnected from supply at instant of voltage peak
(IEC 60335-1/A2)
Not provided with the supply
cord fitted with a plug.
N/A
The appliance is supplied at rated voltage. Any
switch is then placed in the off position and the
appliance is disconnected from the supply mains at
the instant of voltage peak. One second after
disconnection, the voltage between the pins of the
plug is measured with an instrument that does not
appreciably affect the value to be measured
(IEC 60335-1/A1)
N/A
The voltage shall not exceed 34 V
N/A
22.6
Electrical insulation not affected by condensing
water or leaking liquid
Constructed so that the
appliance is prevented from
condensing water or leaking
liquid which may cause a
hazard.
P
Electrical insulation of class II appliances not
affected in case of a hose rupture or seal leak
N/A
Electrical insulation not affected by snow penetration
to appliance enclosure (IEC 60335-2-40)
Considered the indoor unit
only.
N/A