Instruction manual

Page 33 of 100 Report No. 255837
TRF No. IEC60335_2_40F
IEC 60335-2-40
Clause Requirement Test Result Verdict
22.14
No ragged or sharp edges creating a hazard for the
user in normal use, or during user maintenance
No ragged or sharp edges
creating a hazard for the user
in normal use.
Cooling fins are allowed to be
used for its function.
P
No exposed pointed ends of self tapping screws etc.,
liable to be touched by the user in normal use or
during user maintenance
No exposed pointed ends of
self tapping screws etc.
P
22.15
Storage hooks and the like for flexible cords smooth
and well rounded
Smooth and well rounded. P
22.16
Automatic cord reels cause no undue abrasion or
damage to the sheath of the flexible cord, no
breakage of conductors strands, no undue wear of
contacts
No automatic cord reels. N/A
Cord reel tested with 6000 operations, as specified
N/A
Electric strength test of 16.3, voltage of 1000 V
applied
N/A
22.17
Spacers not removable from the outside by hand or
by means of a screwdriver or a spanner
No spacer. N/A
22.18
Current-carrying parts and other metal parts resistant
to corrosion under normal conditions of use
Resistant to corrosion in
normal use.
P
22.19 Driving belts not used as electrical insulation
No driving belts. N/A
22.20
Direct contact between live parts and thermal
insulation effectively prevented, unless material used
is non-corrosive, non-hygroscopic and
non-combustible
P
Compliance is checked by inspection and, if
necessary, by appropriate test
P
22.21
Wood, cotton, silk, ordinary paper and fibrous or
hygroscopic material not used as insulation, unless
impregnated
No such materials. N/A
Requirement does not apply to magnesium oxide
and mineral ceramic fibres used for electrical
insulation of heating elements (IEC 60335-1/A2)
N/A
22.22 Appliances not containing asbestos
No asbestos. P
22.23
Oils containing polychlorinated biphenyl (PCB) not
used
No oil containing PCB. P
22.24
Bare heating elements adequately supported to
prevent contact with accessible metal parts in case
of rupture or sagging (IEC 60335-2-40)
No bare heating elements. N/A
Bare heating elements only used with metal
enclosures (wood or composite enclosures not
allowed) (IEC 60335-2-40)
N/A
22.25
Sagging heating conductors cannot come into
contact with accessible metal parts
No sagging heating conductor. N/A