Instruction manual

Page 34 of 100 Report No. 255837
TRF No. IEC60335_2_40F
IEC 60335-2-40
Clause Requirement Test Result Verdict
22.26
The insulation between parts operating at safety
extra-low voltage and other live parts complies with
the requirements for double or reinforced insulation
N/A
22.27
Parts connected by protective impedance separated
by double or reinforced insulation
N/A
22.28
Metal parts of class II appliances conductively
connected to gas pipes or in contact with water:
separated from live parts by double or reinforced
insulation
N/A
22.29
Class II appliances permanently connected to fixed
wiring so constructed that the required degree of
access to live parts is maintained after installation
N/A
22.30
Parts serving as supplementary or reinforced
insulation fixed so that they cannot be removed
without being seriously damaged, or
P
so constructed that they cannot be replaced in an
incorrect position, and so that if they are omitted, the
appliance is rendered inoperable or manifestly
incomplete
P
22.31
Clearances and creepage distances over
supplementary and reinforced insulation not reduced
below values specified in clause 29 as a result of
wear
The enclosure and internal
parts are adequately fixed by
screws. Clearances and
creepage distances are never
reduced below the required
values as a result of wear.
P
Clearances and creepage distances between live
parts and accessible parts not reduced below values
for supplementary insulation, if wires, screws etc.
become loose
The enclosure and internal
parts are adequately fixed by
screws.
P
22.32
Supplementary and reinforced insulation designed or
protected against deposition of dirt or dust
Constructed so that clearances
and creepage distances are
never reduced below the
required values due to
deposition of dirt or dust.
P
Supplementary insulation of natural or synthetic
rubber resistant to ageing, or arranged and
dimensioned so that creepage distances are not
reduced below values specified in 29.2
No natural or synthetic rubber
for supplementary insulation.
N/A
Ceramic material not tightly sintered, similar material
or beads alone not used as supplementary or
reinforced insulation
No ceramic material for
supplementary or reinforced
insulation.
N/A
Oxygen bomb test at 70 °C for 96 h and 16 h at
room temperature
N/A
Insulating material in which heating conductors are
embedded considered to be basic insulation and not
reinforced insulation (IEC 60335-1/A2)
No heating conductors. N/A