Instruction manual

Page 35 of 100 Report No. 255837
TRF No. IEC60335_2_40F
IEC 60335-2-40
Clause Requirement Test Result Verdict
22.33
Conductive liquids that are or may become
accessible in normal use are not in direct contact
with live parts
No conductive liquids. N/A
Electrodes not used for heating liquids
N/A
For class II constructions, conductive liquids that are
or may become accessible in normal use, not in
direct contact with basic or reinforced insulation
N/A
For class II constructions, conductive liquids which
are in contact with live parts, not in direct contact
with reinforced insulation
N/A
22.34
Shafts of operating knobs, handles, levers etc. not
live, unless the shaft is not accessible when the part
is removed
No such parts. N/A
22.35
Handles, levers and knobs, held or actuated in
normal use, not becoming live in the event of a
failure of basic insulation (IEC 60335-1/A2)
No such parts. N/A
Such parts being of metal, and their shafts or fixings
are likely to become live in the event of a failure of
basic insulation, they are either adequately covered
by insulation material, or their accessible parts are
separated from their shafts or fixings by
supplementary insulation (IEC 60335-1/A2)
N/A
Requirement does not apply to handles, levers and
knobs on stationary appliances other than those of
electrical components, provided they are either
reliably connected to an earthing terminal or earthing
contact, or separated from live parts by earthed
metal
N/A
22.36
Handles continuously held in the hand in normal use
are so constructed that when gripped as in normal
use, the operators hand is not likely to touch metal
parts, unless they are separated from live parts by
double or reinforced insulation
No such parts. N/A
22.37
Capacitors in class II appliances not connected to
accessible metal parts, unless complying with 22.42
N/A
Metal casings of capacitors in class II appliances
separated from accessible metal parts by
supplementary insulation, unless complying with
22.42
N/A
22.38
Capacitors not connected between the contacts of a
thermal cut-out
Not connected. P
22.39 Lamp holders used only for the connection of lamps
No lamp holders. N/A
22.40
Motor-operated appliances and combined
appliances intended to be moved while in operation,
or having accessible moving parts, fitted with a
switch to control the motor. The actuating member of
the switch being easily visible and accessible
Fixed appliance.
No accessible moving parts.
N/A