Instruction manual

Page 36 of 100 Report No. 255837
TRF No. IEC60335_2_40F
IEC 60335-2-40
Clause Requirement Test Result Verdict
Unless appliance can operate continuously,
automatically or remotely without giving rise to a
hazard, appliances for remote operation being fitted
with a switch. Actuating member of switch being
easily visible and accessible (IEC 60335-1/A2)
N/A
22.41
No components, other than lamps, containing
mercury
No components containing
mercury.
P
22.42
Protective impedance consisting of at least two
separate components
N/A
Values specified in 8.1.4 not exceeded if any one of
the components are short-circuited or open-circuited
N/A
22.43
Appliances adjustable for different voltages,
accidental changing of the setting of the voltage
unlikely to occur
Not adjustable for different
voltages.
N/A
22.44
Appliances not have an enclosure shaped or
decorated like a toy (IEC 60335-1/A2)
The enclosure is not shaped or
decorated enough for children
not to treat it as a toy.
P
22.45
When air is used as reinforced insulation, clearances
not reduced below the values specified in 29.1.4 due
to deformation as a result of an external force
applied to the enclosure
Air is not used as reinforced
insulation.
N/A
22.46
Software used in protective electronic circuits is
software class B or C (IEC 60335-1/A1):
Not considered. N/A
22.47
Appliances connected to the water mains withstand
the water pressure expected in normal use
(IEC 60335-1/A1)
Not intended to be connected
to the water mains.
N/A
No leakage from any part, including any inlet water
hose (IEC 60335-1/A1)
N/A
22.48
Appliances connected to the water mains
constructed to prevent backsiphonage of
non-potable water (IEC 60335-1/A1)
Not intended to be connected
to the water mains.
N/A
22.49
Remote operation duration of operation set before
appliance can be started, unless (IEC 60335-1/A2)
N/A
appliance switches off automatically or can operate
continuously without hazard (IEC 60335-1/A2)
N/A
22.50
Controls incorporated in appliance take priority over
controls actuated by remote operation
(IEC 60335-1/A2)
N/A
22.51
Control on appliance being manually adjusted to
setting for remote operation before appliance can be
operated in this mode (IEC 60335-1/A2)
N/A
Visual indication showing that appliance is adjusted
for remote operation (IEC 60335-1/A2)
N/A