TRF No. IEC60335_2_40F
IEC 60335-2-40
Clause Requirement Test Result Verdict
Container shiw no deformation which result in a
hazard (IEC 60335-2-40)
N/A
22.109
Replacement of non-self-resetting thermal cut-outs
does not damage other connections
(IEC 60335-2-40)
No non-self-resetting thermal
cut-outs.
N/A
22.110
Non-self-resetting thermal cut-outs operate without
short-circuiting live parts of different potential and
without causing contact between live parts and
enclosure (IEC 60335-2-40)
No non-self-resetting thermal
cut-outs.
N/A
Test repeated five times without blowing 3 A fuse
which connects appliance to earth (IEC 60335-2-40)
N/A
Electric strength test as specified in clause 16.3 for
supplementary heating elements (IEC 60335-2-40)
N/A
22.111
Manual resetting of thermostats not necessary after
power supply interruption (IEC 60335-2-40)
N/A
22.112
Construction of refrigerating system comply with
requirements of Section 3 of ISO 5149
(IEC 60335-2-40/A1)
Complied with relevant
requirements.
P
22.113
Flammable refrigerant used, refrigerant tubing
protected or enclosed to avoid mechanical damage
(IEC 60335-2-40/A1)
Intended for the use of a non-
flammable refrigerant.
N/A
Tubing protected to extent that it will not be handled
or used for carrying during moving of product
(IEC 60335-2-40/A1)
N/A
Tubing located within confines of cabinet considered
to be protected from mechanical damage
(IEC 60335-2-40/A1)
N/A
22.114
Flammable refrigerant used, low temperature solder
alloys, such as lead/tin alloys, not acceptable for
pipe connections (IEC 60335-2-40/A1)
Intended for the use of a non-
flammable refrigerant.
N/A
22.115
Total refrigerant mass (M) of all refrigerating systems
within appliance employing flammable refrigerants,
not exceed m
3
defined in annex GG
(IEC 60335-2-40/A1)
Intended for the use of a non-
flammable refrigerant.
N/A
22.116
Appliances using flammable refrigerants constructed
that any leaked refrigerant not flow or stagnate so as
to cause fire or explosion hazard in areas within
appliance where electrical components, which could
be a source of ignition and which could function
under normal conditions or in event of leak, fitted
(IEC 60335-2-40/A1)
Intended for the use of a non-
flammable refrigerant.
N/A
Separate components, such as thermostats, which
charged with less than 0,5 g of flammable gas not
considered to cause fire or explosion hazard in event
of leakage of gas within component itself
(IEC 60335-2-40/A1)
N/A