Instruction manual

Page 41 of 100 Report No. 255837
TRF No. IEC60335_2_40F
IEC 60335-2-40
Clause Requirement Test Result Verdict
clamping means so constructed that there is no risk
of bad contact due to cold flow of the solder
N/A
23.10
The insulation and sheath of internal wiring,
incorporated in external hoses for the connection of
an appliance to the water mains, at least equivalent
to that of light polyvinyl chloride sheathed flexible
cord (60227 IEC 52) (IEC 60335-1/A1)
Not intended to be connected
to the water mains.
N/A
24 COMPONENTS
24.1
Components comply with safety requirements in
relevant IEC standards
Complying with IEC or
equivalent standards.
P
List of components (See appended table)
Components not tested and found to comply with
relevant IEC standard for number of cycles specified,
tested in accordance with clause 24.1.1 to 24.1.9
(IEC 60335-1/A2)
Complying with IEC or
equivalent standards.
P
Components not tested and found to comply with
relevant IEC standard, components not marked or
not used in accordance with its marking, tested
under the conditions occurring in the appliance
Complying with IEC or
equivalent standards.
P
Lampholders and starterholders not being tested and
found to comply with relevant IEC standard, tested
as a part of appliance and additionally according to
gauging and interchangeability requirements of
relevant IEC standard (IEC 60335-1/A2)
No such components. N/A
Motor-compressors not tested according to
IEC 60335-2-34 (not necessary to meet all
requirements of IEC 60335-2-34) (IEC 60335-2-40)
Not checked in the appliance. N/A
24.1.1
Capacitors likely to be permanently subjected to the
supply voltage and used for radio interference
suppression or for voltage dividing, complying with
IEC 60384-14, or
Complying with IEC 60384-14. P
tested according to annex F
N/A
24.1.2
Safety isolating transformers complying with
IEC 61558-2-6, or
No such safety isolating
transformer.
N/A
tested according to annex G
N/A
24.1.3
Switches complying with IEC 61058-1, the number of
cycles of operation being at least
10 000, or
No such switches. N/A
tested according to annex H
N/A
If the switch operates a relay or contactor, the
complete switching system is subjected to the test
N/A