Instruction manual

Page 43 of 100 Report No. 255837
TRF No. IEC60335_2_40F
IEC 60335-2-40
Clause Requirement Test Result Verdict
24.1.7
Remote operation of appliance via
telecommunication network, relevant standard for
telecommunication interface circuitry in appliance is
IEC 62151 (IEC 60335-1/A2)
No such remote operation. N/A
24.1.8
Standard for thermal links IEC 60691
(IEC 60335-1/A2)
Incorporated with terminal
block.
Complying with IEC 60691.
P
Thermal links not complying with IEC 60691
considered to be an intentionally weak part for
purposes of clause 19 (IEC 60335-1/A2)
N/A
24.1.9
Relays, other than motor starting relays, tested as
part of appliance (IEC 60335-1/A2)
Approved relays are used.
Checked in the appliance.
P
They also tested in accordance with clause 17 of
IEC 60730-1, number of operations in clause 24.1.4
selected according to relay function in the appliance
(IEC 60335-1/A2) ..................................................... :
Approved relays are used.
Checked in the appliance.
P
24.2 No switches or automatic controls in flexible cords
No such components. P
No devices causing the protective device in the fixed
wiring to operate in the event of a fault in the
appliance
No such devices. P
No thermal cut-outs that can be reset by soldering
No such components. P
24.3
Switches intended for all-pole disconnection of
stationary appliances are directly connected to the
supply terminals and having a contact separation in
all poles, providing full disconnection under
overvoltage category III conditions
No such components. N/A
24.4
Plugs and socket-outlets for extra-low voltage
circuits and heating elements, not interchangeable
with plugs and socket-outlets listed in IEC 60083 or
IEC 60906-1 or with connectors and appliance inlets
complying with the standard sheets of IEC 60320-1
Not applicable. N/A
24.5
Capacitors in auxiliary windings of motors marked
with their rated voltage and capacitance and used
accordingly
Clearly marked. P
Voltage across capacitors in series with a motor
winding does not exceed 1,1 times rated voltage,
when the appliance is supplied at 1,1 times rated
voltage under minimum load
Measured at 1.1 x 240V~ 50Hz
- Auxiliary capacitor for indoor
fan motor: 282 V
Required: < 495V (= 1.1x450V)
P
24.6
Working voltage of motors connected to the supply
mains and having basic insulation that is inadequate
for the rated voltage of the appliance, not exceeding
42 V
No such motors. N/A
In addition, the motors are complying with the
requirements of annex I
N/A