Instruction manual

Page 45 of 100 Report No. 255837
TRF No. IEC60335_2_40F
IEC 60335-2-40
Clause Requirement Test Result Verdict
Appliance provided with a set of supply leads
accommodated in a suitable compartment
N/A
Appliance provided with a set of terminals and cable
entries, conduit entries, knock-outs or glands,
allowing connection of appropriate type of cable or
conduit
N/A
25.4
Cable and conduit entries, rated current of appliance
not exceeding 16 A, dimensions according to
table 10
N/A
Introduction of conduit or cable does not reduce
clearances or creepage distances below values
specified in 29
N/A
25.5 Method for assemble supply cord with the appliance:
- type X attachment
N/A
- type Y attachment
Type Y attachment. P
- type Z attachment, if allowed in part 2
N/A
Type X attachment, other than those with a specially
prepared cord, not used for flat twin tinsel cords
Type Y attachment. N/A
25.6 Plugs fitted with only one flexible cord
No plugs provided with. N/A
25.7 Supply cords being one of the following types (IEC 60335-1/A2):
- rubber sheathed (at least 60245 IEC 53)
(IEC 60335-1/A2)
N/A
- polychloroprene sheathed (at least 60245 IEC 57)
(IEC 60335-1/A2)
N/A
- cross-linked polyvinyl chloride sheathed (at least
60245 IEC 87) (IEC 60335-1/A2)
N/A
Polyvinyl chloride sheathed:
Not used if they are likely to touch metal parts having a temperature rise exceeding
75 K during clause 11 (IEC 60335-1/A2)
- light polyvinyl chloride sheathed cord (at least
60227 IEC 52), appliances not exceeding 3 kg
(IEC 60335-1/A2)
N/A
- ordinary polyvinyl chloride sheathed cord (at least
60227 IEC 53), other appliances (IEC 60335-1/A2)
N/A
Heat resistant polyvinyl chloride sheathed:
Not used for type X attachment other than specially prepared cords
(IEC 60335-1/A2):
- heat-resistant light polyvinyl chloride sheathed cord
(at least 60227 IEC 56), appliances not exceeding
3 kg (IEC 60335-1/A2)
N/A
- heat-resistant polyvinyl chloride sheathed cord
(60227 IEC 57), other appliances (IEC 60335-1/A2)
N/A