Instruction manual

Page 47 of 100 Report No. 255837
TRF No. IEC60335_2_40F
IEC 60335-2-40
Clause Requirement Test Result Verdict
- separation of the conductor from its terminal
N/A
- loosening of any cord guard
N/A
- damage, within the meaning of the standard, to the
cord or the cord guard
N/A
- broken strands piercing the insulation and
becoming accessible
N/A
25.15
Conductors of the supply cord relieved from strain,
twisting and abrasion by use of cord anchorage
Adequate cord anchorages are
used.
P
The cord cannot be pushed into the appliance to
such an extent that the cord or internal parts of the
appliance can be damaged
P
Pull and torque test of supply cord, values shown in
table 12: pull (N); torque (not on automatic cord reel)
(Nm) .......................................................................... :
Pull force: 100 N
Torque: 0,35 Nm
P
Max. 2 mm displacement of cord
Less than the value specified. P
Creepage distances and clearances not reduced
below values specified in clause 29.1
Not reduced. P
25.16 Cord anchorages for type X attachments constructed and located so that:
- replacement of the cord is easily possible
Type Y attachment. N/A
- it is clear how the relief from strain and the
prevention of twisting are obtained
N/A
- they are suitable for different types of cord
N/A
- cord cannot touch the clamping screws of cord
anchorage if these screws are accessible, unless
separated from accessible metal parts by
supplementary insulation
N/A
- the cord is not clamped by a metal screw which
bears directly on the cord
N/A
- at least one part of the cord anchorage securely
fixed to the appliance, unless part of a specially
prepared cord
N/A
- screws which have to be operated when replacing
the cord do not fix any other component, if
applicable
N/A
- if labyrinths can be bypassed the test of 25.15 is
nevertheless withstood
N/A
- for class 0, 0I and I appliances: they are of
insulating material or are provided with an
insulating lining, unless a failure of the insulation of
the cord does not make accessible metal parts live
N/A
- for class II appliances: they are of insulating
material, or if of metal, they are insulated from
accessible metal parts by supplementary insulation
N/A